Analysis of channel gate manufacturers What are the common faults in the use of swing gates, wing gates, and tripod turnstile ?

16-05-2021

Analysis of channel gate manufacturers What are the common faults in the use of swing gates, wing gates, and tripod turnstile ?


Abstract: As a channel gate product, swing gates, wing gates, and tripod turnstile will inevitably have some faults that affect the normal operation of the equipment. Now the editor of Chuangxintong will analyze the use of swing gates, wing gates, and tripod turnstile for everyone Common problems in the process and a method to solve these problems hope to help you. 1. Swing gates, wing gates, and tripod turnstile cannot be turned on the direction indicator after energizing

    As a channel gate product, swing gates, wing gates, and tripod turnstile  will inevitably have some faults that affect the normal operation of the equipment. Now the editor of Chuangxintong will analyze the common use of swing gates, wing gates, and tripod turnstile. Problems and a way to solve these problems hope to help you.

 

 

  1. The direction indicator of the swing gate, wing gate, and tripod turnstile cannot be displayed normally after the power is turned on, and the device cannot read the card normally. The main reason for this type of failure is the abnormality of the equipment power system, and we should carefully check the equipment main controller Whether the fuse is damaged, whether the connector is loose, whether the power cord is disconnected, etc.;

 

 

  2. The swing gate, wing gate, and tripod turnstile cannot be opened after the card is read. The gate can be opened by manual or remote control. The cause of this type of failure should occur when the card reader device and the gate control board are disconnected or the reading head fails. , It is recommended to contact the relevant technicians for inspection and maintenance when such failures occur.

 

 

  3. During the use of swing gates, wing gates, and tripod turnstile, the swing arm cannot be locked normally. This type of failure is mainly due to the damage of the electromagnet or the disorder of the equipment control program. The electromagnet should be replaced and whether there is a problem with the control program;

 

 

  4. Swing gates, wing gates, and tripod turnstile cannot read cards normally. Check whether the wiring between the card reader device and the main controller is loose or the card reader device is damaged. The card reader device should be replaced if it is damaged. The gate is in normal use.