Five major fault phenomena and treatment methods of tripod turnstile

11-07-2022

      Five major fault phenomena and treatment methods of tripod turnstile


Abstract: With the further increase in the traffic demand of the road network in and out of the city in the big city, the traffic safety, traffic efficiency and stability of the road network in the joint area will become more prominent under the uncontrolled state. The tripod turnstile is no longer a simple road section in the traditional sense of traffic engineering, but has become the responsibility of the joint road network traffic through implementation control.

With the further increase in the traffic demand of the road network in and out of the city, the traffic safety, traffic efficiency and stability of the road network in the joint area will become more prominent under the uncontrolled state. It is not only the road sections and nodes that should be properly selected. Implementing ramp control, the tripod turnstile is no longer a simple road section in the traditional sense of traffic engineering, but becomes a buffer, buffer, slow release, and integrated multi-functional body that undertakes the transition of traffic flow in the road network at the junction through implementation control. It is the main implementation carrier of traffic flow conversion and control in the road network.




The five fault phenomena and treatment methods of the tripod turnstile:


1. Fault phenomenon: the indicator light of the tripod turnstile does not light up


Treatment method: check the power supply or fuse


2. Fault phenomenon: there is a crash sound when the tripod turnstile is opened


Processing method: adjust the strength of the damper


3. Fault phenomenon: there is a buzzing sound when the tripod turnstile is opened


Treatment method: Adjust the four base angle screws of the electromagnet to reduce the suction gap of the electromagnet


4. Fault phenomenon: the tripod turnstile cannot be opened


  Approach:


1. Check the control panel;


2. Check whether the electromagnet screw is loose or broken;


3. Check the drive board of the tripod turnstile. At this time, you can short-circuit the input end of the drive board (1# open gate or 2# open gate input), if the solenoid valve or the green light has a response, it is normal


5. Fault phenomenon: the tripod turnstile cannot be moved manually


  Approach:


1. Check whether the electromagnet of the power drop bar attracts the iron block;


2. Whether there is DC12V power supply for the electromagnet of the power down rod;


3. Check whether the electromagnetic device of the power-off drop bar pushes against the spring plate in the turntable. If so, move the whole device up so that the two do not come into contact.


The above is about the "five fault phenomena and treatment methods of the tripod turnstile". If you have any other questions, please contact the technical staff of Chuangxintong Technology for assistance.