Reset function and self-check prompt function
Reset function and self-check prompt function
Illegal crossing reset function in normally open state
When an illegal intruder pushes the brake lever in the direction of passage, it is locked by turning a certain angle (about 5 degrees), and the lock is locked at the same time as the sound alarm. At this time, if the push rod force continues to be applied, the brake lever continues to move forward
Rotate in the direction, within the range of 5~10°, alarm and automatically try to reset. After the reset is successful, the alarm will be cancelled;
But the brake lever is locked at an angle of 10 degrees from the horizontal, and it keeps alarming, and it needs to be cancelled after receiving a valid opening signal
Alarm and reset.
Direction indicator
There are two types of pass signs, red "x" no-go sign and green "↑". When received
When the gate opening signal is in effect, the traffic prompt changes from the red "x" forbidden sign to the green "↑" sign (arrow
Head pointing to the direction of passage), allowing passage; after valid passage or not passing within valid passage time, passage
The sign changed from a green "↑" pass sign to a red "x" prohibition sign.
Note: The prohibition status of the access notification is red "x", and the access symbol is green "ö".
Voice prompts
Alarm prompt function
Illegal entry in the normally open state: the alarm will prompt, and it will stop when it is released.
Forced rod drop signal interface
After receiving the forced bar fall signal, the three-roller gate will drop the bar, and pedestrians can pass freely;
The machine automatically goes up the pole and returns to the state set before the down pole. Receive switch signal (+12V level signal).
Single and two-way current limit can be set on site
This system sets the working mode
a) Normally open
Left to free, right to free; left to free, right to control; left to free, right to prohibit
Left controlled Free right; Left controlled Right controlled; Left controlled Right prohibited
Left to prohibit Right to free; Left to prohibit Right to control; Left to prohibit Right to prohibit
b) Normally closed
Left controlled, right controlled; left controlled, right prohibited
Left to prohibit, right to control; left to prohibit, right to prohibit
Self-check failure alarm prompt function
When the gate is powered on, the equipment is checked. If a fault is found, the system will enter
Alarm, and the fault code is displayed through the digital tube to facilitate maintenance and repair.
Reserve standard interfaces for easy integration.